Customization: | Available |
---|---|
Application: | Construction, Underground, Power Station, Telecommunication |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Self-supporting Armoured fiber optic cable single mode Figure 8 optical fiber cable
Construction :
Solid & stranded Aluminium wire
Techical Data :
Standard:IEC 60502-1 / VDE 0276 /NT88-22
Fixed installed: -15ºC up to 70ºC
At short circuit of max.5s up to 160ºC
Nominal Voltage : 600/1000V
Min inner bending radius:
Single coe:15D
Multi core:12D
Behaviour in fire:
Flame retardant cable acc.to IEC60332-1
Application:
PVC power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.
Technical Parameters:
No.of cores x Nominal section area | Nominal Construction of conductor | Nominal Insulation thickness |
Nominal Sheath thickness |
Nominal Overall diameter |
Nominal Cable weight |
Max.Resistance of conductor at 20ºC |
No.X mm² | No.X mm | mm | mm | mm | kg/km | <=(Ω/km) |
Three core PVC Power Cables CU/XLPE/PVC( AL/XLPE/PVC ) | ||||||
3x1.5 | 2x 1.38 | 0,7 | 1,8 | 11.3 | 130 | 12,10 |
3x2.5 | 7 x 0,67 | 0,7 | 1,8 | 11.8 | 170 | 7,41 |
3x4.0 | 7 x 0,85 | 0,7 | 1,8 | 13.1 | 230 | 4,61 |
3x6.0 | 7 x 1,04 | 0,7 | 1,8 | 13.9 | 305 | 3,08 |
3x10 | 7 x 1,35 | 0,7 | 1,8 | 17.5 | 450 | 1,83 |
3x16 | 7 x 1,70 | 0,7 | 1,8 | 18.2 | 615 | 1,150 |
3x25 | 7 x 2,14 | 0,9 | 1,8 | 19.1 | 870 | 0,727 |
3x35 | 7 x 2,52 | 0,9 | 1,8 | 21.1 | 1155 | 0,524 |
3x50 | 19 x 1,78 | 1,0 | 1,8 | 23.8 | 1530 | 0,387 |
No.of cores x Nominal section area | Nominal Construction of conductor | Nominal Insulation thickness |
Nominal Sheath thickness |
Nominal Overall diameter |
Nominal Cable weight |
Max.Resistance of conductor at 20ºC |
No.X mm² | No.X mm | mm | mm | mm | kg/km | <=(Ω/km) |
Four core PVC Power Cables CU/XLPE/PVC( AL/XLPE/PVC ) | ||||||
4x1.5 | 2x 1.38 | 0,7 | 1,8 | 12.1 | 150 | 12,10 |
4x2.5 | 7 x 0,67 | 0,7 | 1,8 | 13.2 | 200 | 7,41 |
4x4.0 | 7 x 0,85 | 0,7 | 1,8 | 14.9 | 275 | 4,61 |
4x6.0 | 7 x 1,04 | 0,7 | 1,8 | 16.1 | 370 | 3,08 |
4x10 | 7 x 1,35 | 0,7 | 1,8 | 18.6 | 560 | 1,83 |
4x16 | 7 x 1,70 | 0,7 | 1,8 | 20.2 | 795 | 1,150 |
4x25 | 7 x 2,14 | 0,9 | 1,8 | 21.8 | 1130 | 0,727 |
4x35 | 7 x 2,52 | 0,9 | 1,8 | 24.1 | 1515 | 0,524 |
4x50 | 19 x 1,78 | 1,0 | 1,9 | 27.5 | 2010 | 0,387 |
4x70 | 19 x 2,14 | 1,1 | 2,0 | 31.7 | 2860 | 0,268 |
4x95 | 19 x 2,52 | 1,1 | 2,1 | 35.4 | 3870 | 0,193 |
4x120 | 37 x 2,03 | 1,2 | 2,3 | 39.2 | 4850 | 0,153 |
4x150 | 37 x 2,25 | 1,4 | 2,4 | 43.8 | 5980 | 0,124 |
4x185 | 37 x 2,52 | 1,6 | 2,6 | 48.7 | 7480 | 0,0991 |
4x240 | 61 x 2,25 | 1,7 | 2,8 | 54.4 | 9735 | 0,0754 |
4x300 | 61 x 2,52 | 1,8 | 3,0 | 59.9 | 12120 | 0,0601 |
Product Show:
Power cables is used in power transmission and distribution line.It does not only have excellent electric, mechanical properties,but also has powerfulresistance against chemical corrosion, heat aging and environmental stress.
Features:
Conductor: creep resistance, high flexibility, strong extended, low rebound, connection stability.
Insulation: high temperature resistant, anti-burning, anti-aging, strong and durable, low-carbon environment.
Armored layer: Lower cost and better performance, a special form of interlocking, sturdy and tough.
Outer sheath:without lead, cadmium in PVC, can be installed in wet or damp locations, can also be directly buried or laid in the construction.